Water analysis without letting turbidity get in the way.

Handheld colorimetry for turbid samples.

IC-VIS™ combines standard colorimetric analysis with Instant Clarity™ turbidity compensation, for measurements in challenging liquid samples with less sample preparation.

Discuss your methodExplore methods →
4 wavelengths
420 · 520 · 560 · 610 nm
690 g
Handheld · 4 × AA battery
QR methods
Load methods · Export results
IC-VIS™ carrying case open at a wastewater treatment plant, with reagent vials and the handheld instrument beside the process water
In the field
Jump toWhy IC-VIS™How it worksInstant Clarity™MethodsSample formatsQR workflowWastewaterSpecs
— Why IC-VIS™

Measure turbid samples without first removing the turbidity.

Turbidity in a sample can add its own optical contribution to a colorimetric reading. IC-VIS™ is designed to compensate for that contribution with Instant Clarity™, reducing how often a turbid sample needs to be filtered or pre-treated for optical reasons alone. Sample preparation required by the chemistry of a specific reagent method may still apply.

Conventional colorimetric workflow
Turbid sample
Filter / pre-treat (turbidity-dependent)
Add reagent
Measure
IC-VIS™
Turbid sample
Add reagent / method
Measure with Instant Clarity™
— How it works

Prepare. Insert. Measure.

A gloved hand preparing a colorimetric reagent sample in the laboratory
01

Prepare

Prepare the sample and the reagent method.

A cuvette being lowered into the IC-VIS™ cuvette port
02

Insert

Insert the cuvette into IC-VIS™.

The IC-VIS™ screen showing "Measuring..." during a measurement
03

Measure

IC-VIS™ measures and displays the result.

— Instant Clarity™

Compensating for the turbidity in a colorimetric reading.

Colorimetric chemistry measures the color response of a reagent. Turbidity can add an unwanted optical contribution on top of that response. IC-VIS™ is designed to compensate for the turbidity contribution, so the chemical response can be measured more reliably in cloudy samples.

Same analyte concentration
Low-turbidity sample
Colorimetric measurement
Higher-turbidity sample
Colorimetric measurement
Instant Clarity™
Turbidity compensation
Comparable concentration result
— Four wavelengths, many methods

One handheld instrument, many colorimetric methods.

420 nm
520 nm
560 nm
610 nm

IC-VIS™ combines four fixed visible wavelengths with preprogrammed and programmable measurement methods, supporting reagent-based colorimetric methods whose optical response is compatible with these wavelengths — including:

PhosphateNitrate & nitriteAmmoniumChlorineCODTOC
Explore the Method Library →
A row of Hach LCK reagent test-kit cuvettes in a range of colors, from blue and green through yellow, orange and pink, representing different colorimetric methods
— Flexible sample formats

Adapt the optical path to the sample.

Alongside standard 16 mm round, 13 mm round and 10 mm square cuvettes, IC-VIS™ also accepts a 10 mm square-format cuvette with a shorter 3 mm optical path. The shorter path can help extend the usable measurement range for strongly absorbing or higher-concentration samples on suitable methods — moving a method between path lengths still needs method-specific consideration, not an automatic transfer.

16 mm round
16 mm path
Larger-volume samples
13 mm round
13 mm path
Standard round format
10 mm square
10 mm path
Standard optical path
3 mm short-path
3 mm path
For strongly absorbing / high-concentration samples
— Method workflow

Choose → QR-code → Scan → Done!

Choose a method
Method Library or Configurator
QR code
Unique to the method and device
Scan with IC-VIS™
No cables, no manual entry

The same QR-code workflow moves data the other way too — export measurement results from IC-VIS™ by QR code, for logging or further use.

Method Library →Configurator →Data Export →
— Real application

Industrial and municipal wastewater.

Turbid wastewater discharging into a treatment channel

Reagent-based wastewater parameters are well established, but the measurement is usually tied to a lab bench — and suspended solids in the sample can bias a colorimetric reading. IC-VIS™ pairs the same established reagent-kit chemistry with a portable measurement and Instant Clarity™ turbidity compensation, with methods loaded by QR code.

Method Library coverage today
COD · nitrate · nitrite · ammonium · phosphate · chlorine · TOC
Reagent-kit suppliers
Hach · Macherey-Nagel · Merck · Lovibond
Read the case study →
— Portable by design

Take the measurement to the sample.

IC-VIS™ is battery-powered and handheld, built for measurements at the sampling point rather than a fixed benchtop instrument.

690 g
Weight
4 × AA
Battery
3 formats
Cuvette compatibility
A technician in high-visibility clothing at a wastewater treatment plant, with a carrying case beside the sampling rail

Turbid samples

Compensate for turbidity with Instant Clarity™ instead of always having to remove it first.

Flexible methods

Use compatible reagent-based colorimetric methods across four fixed wavelengths.

Portable workflow

Measure close to where the sample is taken, then move the result on by QR code.

— Specification

IC-VIS™ at a glance.

View full specification
Wavelengths420, 520, 560, 610 nm
Photometric range0–3 Abs
Photometric accuracy±0.03 Abs
Cuvettes10 mm square (standard or 3 mm short-path); 13 mm round; 16 mm round
MethodsPreprogrammed and programmable
Data storage / transfer50 latest measurements; QR-code transfer
Battery4 × AA
Typical battery life~2 months at 10 measurements/day, 5 days/week
Dimensions215 × 96 × 60 mm
Weight690 g
DisplayBacklit LCD-IPS
LanguageEnglish

Specifications are indicative and may depend on configuration and method.

— Downloads & support

Manuals, declarations and method resources.

Have a turbid water sample?

Tell us what you measure today, and we can check whether your existing colorimetric method can be used with IC-VIS™.

Discuss your methodExplore the Method Library